LED display is not working when connecting to power supply
Make sure the outlet has 110V/220V power
Make sure the power wire is well connected to a outlet
Check the fuse of the wire terminals is intact
Make sure the plug from the transmitter is connected to the control panel
Please try with a new control panel
Cannot finish the remote pairing
Make sure there is a battery in the remote
Make sure if you turn ON the lock of the remote (PR4)
Check if the LED is ON when press any button of the remote
Check if the LED display on the control panel will blink when press any button of the remote
Make sure if you follow the correct remote pairing procedures in the manual
Motor wire connection
Please refer to the manual to check if the wire connection is correct
Make sure the motor wires connection are correct, especially for Swing gate opener
Make sure the limit switch wires are connected, especially for Sliding gate opener
Make sure the Hall sensor wires are connected, especially for Garage door opener
Make sure the Stop terminal (NC) is connected with a Jumper, especially for PSA motor
Preperation before the system learning
Make sure if the motor runs smoothly
Make sure the gate moves smoothly
Make sure the motor is un-released
Make sure the motor mode is correct (Over-current/Limit switch/Hall sensor)
Cannot finish the system learning
Make sure if you follow the correct system learning procedures in the manual
Check below parameters;
1) Make sure the motor mode is correct (Over-current/Limit switch/Hall sensor)
2) Check the setting of Dual gate/Single gate
3) Check if the over-current setting is too low
4) Check if the photocells switch is ON but not connected to photocells.
5) Check if pre-flash function is OFF
Return to the default setting and try again